临安HX-FDR series switch controller
Category:
Product Description
Product Overview
The HX-FDR series intelligent controller is a classic intelligent control terminal launched by our company and has been widely used in power distribution projects across various regions. Installed at the responsibility boundary points of overhead power distribution lines, it works with boundary circuit breakers and other equipment to protect branch lines. It can automatically cut off phase-to-ground faults, phase-to-phase short circuits, overcurrents, and other faults on the line, ensuring the safe power supply for non-faulty users. It collects real-time data of three-phase current and zero-sequence current (four analog signals); with a liquid crystal display interface and key input, human-machine operation is simple and fast; it uses a 32-bit ARM high-speed single-chip microcomputer as the main control chip, with fast running speed, sensitive and accurate detection, and timely and rapid protection action. The product has local/remote switching functions and offers selectable communication methods including local serial port parameter setting, GSM SMS control, and GPRS wireless communication, making it widely applicable to the control and protection of 10KV~66KV overhead power distribution lines in urban and rural areas.
Functions
◇High-speed protection
◇Surge protection
◇Real-time status query
◇Overcurrent protection
◇Zero-sequence protection
◇GPRS communication (optional)
◇Event recording
◇Accelerated reclosing
◇Local/remote setting of setpoints (optional)
◇Three-time reclosing
◇Real-time clock
Main Technical Parameters
| Serial Number |
Item |
Specified Value |
Remarks |
|
| 1 |
Operating Voltage |
AC220V |
±15% |
|
| 2 |
Operating Voltage Frequency |
50Hz |
||
| 3 |
Overall Power Consumption |
<10W |
||
| 4 |
Output Control Method (Closing/Opening Operation) |
Normally Open Contact |
Selectable, load capacity 250V/5A |
|
| 5 |
6-way switch quantity input loop |
Selectable |
AC/DC220V; AC/DC110V; DC24V |
|
| 6 |
Phase Current Sampling Input Value Range |
0~30A |
Secondary Value |
|
| 8 |
Zero-sequence Current Sampling Input Value Range |
0~10A |
Primary Value |
|
| 9 |
Phase Current Sampling Error |
±0.5% |
||
| 10 |
Zero-sequence Current Sampling Error |
±0.2% |
||
| 11 |
Phase-to-phase Short Circuit Overcurrent Protection Setpoint |
0.5~30A |
Secondary Value (step 0.01A) |
|
| 12 |
Phase-to-phase Short Circuit Overcurrent Protection Operating Time |
0~3S |
Secondary Value (step 0.01S) |
|
| 13 |
Single-phase Grounding Protection Current Setpoint |
0.01~5A |
Secondary Value (step 0.005A) |
|
| 14 |
Single-phase Grounding Protection Time Setpoint |
0~30S |
Secondary Value (step 0.01S) |
|
| 15 |
Remote Control Distance |
Within 50 meters |
||
Controller Dimensions Diagram