喀什JP Low-voltage Comprehensive Distribution Box

The JP series low-voltage integrated power distribution device (hereinafter referred to as the integrated distribution box) is mainly suitable for AC 50Hz urban and rural power grids with a rated voltage of 0.4kV or lower. It is installed on the low-voltage side of 10/0.4KV outdoor transformers; it has multiple functions such as power distribution, power metering, data acquisition, voltage monitoring, overcurrent protection, phase-loss protection, low-voltage lightning protection, leakage protection, automatic reclosing after fault clearance, and reactive power compensation. This new outdoor low-voltage power distribution device is characterized by its small size, easy installation, anti-theft, low cost, strong adaptability, aging resistance, accurate commissioning, and no compensation error. It has high protection level, perfect protection performance, and high degree of automation. It is also suitable for on-site power distribution and control, and can be used as an auxiliary device for other power distribution equipment. It is an ideal product for power grid transformation. This product complies with GB7251.1 standard and has passed CQC certification. The reactive power compensation device has passed the test of the quality inspection and testing center, and all indicators meet the JB7113 standard for low-voltage parallel capacitor devices.

Product Description

Product Overview

The JP series low-voltage integrated power distribution device (hereinafter referred to as the integrated distribution box) is mainly suitable for 50Hz AC power distribution systems with a rated voltage of 0.4kV or less in urban and rural power grids. It is installed on the low-voltage side of a 10/0.4KV outdoor substation; it integrates multiple functions such as power distribution, power metering, data acquisition, voltage monitoring, overcurrent protection, phase failure protection, low-voltage lightning protection, leakage protection, automatic reclosing after fault clearance, and reactive power compensation. This new outdoor low-voltage power distribution device has advantages such as small size, easy installation, anti-theft, low cost, strong adaptability, anti-aging, accurate commissioning, and no compensation error. It also has high protection level, complete protection performance, and high degree of automation. It is also suitable for on-site power distribution control and can be used as a supporting auxiliary device for other power distribution equipment, making it an ideal product for grid transformation. This product complies with GB7251.1 standard and has passed CQC certification. The reactive power compensation device has passed the testing of the quality inspection and testing center, and all indicators meet the JB7113 standard for "Low-voltage parallel capacitor devices".

The metering device is designed and installed with three single-phase low-voltage test meters or a three-phase four-wire electricity meter. The accuracy level of the current transformer is 0.2S, which is conducive to the balance of the three-phase load and ensures accurate metering.

The reactive power compensation device uses fixed or automatic compensation, and the compensation capacity is greater than or equal to 15~20% of the transformer capacity. A leakage protection device and an AC contactor are installed. The leakage protection device has short-circuit, overload, leakage, and alarm functions; it works with the AC contactor to achieve automatic reclosing, and it can also be used with a household leakage protector to achieve hierarchical protection, ensuring safe operation of the equipment and preventing accidents caused by leakage.

The integrated distribution box is made of matte stainless steel or SMC material. This box has good heat dissipation, rainproof, dustproof, anti-condensation, anti-heat radiation, and anti-light pollution characteristics.

 

Technical Parameters

Project Name

Unit

Parameter

Rated Operating Voltage

V

400

Rated Insulation Voltage

V

660

Rated Circuit Current

A

100, 160, 200, 400, 500, 600, 800

Rated Frequency

Hz

50

Insulation Resistance

MQ

≥4

Dielectric Strength

Main Circuit to Ground

KV

2.5KV, 1 minute

Auxiliary Circuit to Ground

KV

2.5KV, 1 minute

Rated Withstand Current

1-second rated short-time withstand current

KA

6.3KA

Rated Peak Withstand Current

KA

10.5KA

Protection Level

 

IP33

System Grounding Method

 

Neutral point directly grounded (TT or TN system)