北海JCZ2/(800A, 1000A, 1250A, 2000A)/1.14KV

The company, with its strong technical force, complete equipment testing, mature production processes, rich technical experience, strict product quality assurance, sincere service attitude and after-sales service, provides users with excellent and distinctive products and services.

Product Description

Technical Parameters:

Model

JCZ2-800/

1.14(2)KV

JCZ2-1000/

1.14(2)KV

JCZ2-1250/

1.14(2)KV

JCZ2-2000/

1.14(2)KV

Main Circuit Rated Voltage (KV)

Main Circuit rated Voltage(KV)

1140(2000)

1140(2000)

1140(2000)

1140(2000)

Main Circuit Rated Current (A)

Main Circuit rated Current(A)

800

1000

1250

2000

Main Circuit Making Capacity (A/100 times)

Main Circuit Current making ability(A/100T)

8000

6000

6000

6000

Main Circuit Breaking Capacity (A/10 times)

Main Circuit break-make ability(A/10T)

6400

5000

5000

5000

Maximum Breaking Capacity (A/3 times)

Maximum Break Ability(A/3T)

8000

6000

5000

6000

Electrical Life AC3 (10,000 times)

Electricity Life AC3(10ST)

20

20

20

20

Electrical Life AC4 (10,000 times)

Electricity Life AC4(10ST)

0.5

0.5

0.5

0.5

Mechanical Life (10,000 times)

Mechanical Life(10ST)

100

100

100

100

Rated Operating Frequency AC3 (times/h)

Rated Frequency AC3(T/h)

120

120

120

120

Rated Operating Frequency AC4 (times/h)

Rated Frequency AC3(T/h)

300

300

300

300

Short-Time Operating Frequency times/h (20S)

Short Time Operate Frequency

T/h(20S)

3000

3000

3000

3000

Rated Distance (mm)

Rated Space(mm)

3±0.2

3±0.2

3±0.2

3±0.2

Overtravel (mm)

Over travel During Opening Max(mm)

1.5±0.2

1.5±0.2

1.5±0.2

1.5±0.2

 

 

JCZ2-1000A to 2000A/2KV Dimensions and Structure Diagram

 