ZN63A-12 Indoor High Voltage Vacuum Circuit Breaker

The ZN63A-12 type permanent magnet indoor high-voltage vacuum circuit breaker is a three-phase AC 50Hz indoor switching device with a rated voltage of 12kV for power systems. It serves as a protection and control unit for power grid equipment and industrial and mining enterprise power equipment. It is suitable for occasions requiring frequent operation under rated operating current or multiple breaking of short-circuit current.

Keywords:

ZN63A-12 Indoor High Voltage Vacuum Circuit Breaker

Telephone:

  • Product details
    • Commodity name: ZN63A-12 Indoor High Voltage Vacuum Circuit Breaker

    The ZN63A-12 type permanent magnet indoor high-voltage vacuum circuit breaker is a three-phase AC 50Hz indoor switching device with a rated voltage of 12kV for power systems. It serves as a protection and control unit for power grid equipment and industrial and mining enterprise power equipment. It is suitable for occasions requiring frequent operation under rated operating current or multiple breaking of short-circuit current.

    Overview

    The ZN63A-12 type permanent magnet indoor high-voltage vacuum circuit breaker is a three-phase AC 50Hz indoor switching device with a rated voltage of 12kV for power systems. It serves as a protection and control unit for power grid equipment and industrial and mining enterprise power equipment. It is suitable for occasions requiring frequent operation under rated operating current or multiple breaking of short-circuit current.

    This circuit breaker adopts an integrated design of the operating mechanism and the circuit breaker body. It can be used as a fixed installation unit or equipped with a special pushing mechanism to form a handcart unit.

     

    Main Technical Parameters

    Serial Number

    Name

    Unit

    Data

    1

    Rated Voltage

    kV

    12

    2

    Rated Frequency

    Hz

    50

     

    3

    Rated Insulation Level

    1min Power Frequency Withstand Voltage

     

    kA

    Ground/Phase 42/48

    Lightning Impulse Withstand Voltage (Peak)

    Ground/Phase 75/85

    4

    Rated Short-Circuit Breaking Current

    kA

    20

    25

    31.5

    40

     

    5

    Rated Current

     

    A

    630

    630

    12501600

    12501600

    1250

    1250

    20002500

    20002500

    6

    Rated Short-Time Withstand Current (RMS)

    kA

    20

    125

    31.5

    40

    7

    Rated Peak Withstand Current (Peak)

    kA

    50

    63

    80

    100

    8

    Rated Short-Circuit Closing Current (Peak)

     

    50

    63

    80

    100

    9

    Rated Short-Circuit Current Duration

    S

    4

    10

    Mechanical Life

    Times

    10000

    11

    Secondary Circuit Power Frequency Withstand Voltage (1min)

    V

    2000

    12

    Rated Operating Sequence

     

    Open-t-Close-Open-t1-Close-Open

    Note: 20kA、31.5kAt=0.3st1=180s;40kAt=180s;tl=180s

     