ZN63A-12(VS1) indoor high-voltage vacuum circuit breaker

The ZN63A-12(VS1) type indoor high-voltage vacuum circuit breaker is a three-phase AC 50Hz indoor device with a rated voltage of 12kV. It can be used for control and protection of electrical facilities in factories, mines, enterprises, power plants, and substations.

Keywords:

ZN63A-12(VS1) indoor high-voltage vacuum circuit breaker

Telephone:

  • Product details
    • Commodity name: ZN63A-12(VS1) indoor high-voltage vacuum circuit breaker

    The ZN63A-12(VS1) type indoor high-voltage vacuum circuit breaker is a three-phase AC 50Hz indoor device with a rated voltage of 12kV. It can be used for control and protection of electrical facilities in factories, mines, enterprises, power plants, and substations.

    Product Overview

    The ZN63A-12(VS1) indoor high-voltage vacuum circuit breaker is a three-phase AC 50Hz indoor device with a rated voltage of 12kV. It can be used for control and protection of electrical facilities in factories, enterprises, power plants, and substations. The ZN63A-12 indoor high-voltage vacuum circuit breaker can be installed in both trolley-type switchgear and fixed switchgear. This circuit breaker has advantages such as long life, simple maintenance, no pollution, no explosion hazard, and low noise. The operating mechanism is spring-energy storage type, which can be operated by AC or manually; and it is suitable for harsh working conditions such as frequent operation.

     

    Working Principle

    The energy required for the circuit breaker to close is supplied by the spring energy storage mechanism. The energy storage mechanism can be driven by an external power supply motor or manually. After energy storage is complete, the energy storage indicator shows "Energy Stored". At the same time, the energy storage switching switch cuts off the power supply of the energy storage motor, and the circuit breaker is in the ready-to-close state. During the closing operation, whether the "Close" button is pressed manually or the closing electromagnet is activated by remote operation, the circuit breaker can be closed. After the closing operation is completed, the energy storage indicator and energy storage switching switch reset, the motor power is turned on, and the motor stores energy again. The closing indicator shows "Closed", and the auxiliary switch contacts are switched. During the tripping operation, whether the "Trip" button is pressed manually or the closing electromagnet is activated by remote operation, the circuit breaker can be tripped. After the tripping operation is completed, the tripping indicator shows "Tripped", and the auxiliary switch contacts are switched. At the same time, during the tripping operation, the counter automatically advances one position, and the corresponding number can be seen from the panel viewing window.

     

    Serial Number

    Name

    Unit

    Value

    1

    Rated Voltage

    KV

    12

    2

    Rated Insulation Level

    1min Power Frequency Withstand Voltage

    KV

    42

    Impulse Withstand Voltage

    75

    3

    Rated Current

    A

     

    60

    120

    12501600

    20002500

     

    125016002000250031504000

     

    4000

    5000

    4

    Rated Short-Circuit Breaking Current

     

     

    kA

    20

    25

    31.5

    40

    50

    5

    Rated Short-Circuit Making Current (Peak)

    50

    63

    80

    100

    130

    6

    Rated Dynamic Stability Current (Peak)

    50

    63

    80

    100

    130

    7

    Rated Thermal Stability Current (RMS)

    20

    25

    31.5

    40

    50

     

    8

    Rated Short-Circuit Breaking

    Current Breaking Times

    31.5kA

     

    Times

    50

    40kA

    30

    50KA

    20

    9

    Rated Thermal Stability Time

    s

    4

    10

    Rated Operating Sequence

     

    Trip-0.3s-Close-Trip-180s-Close-Trip

    Trip-180s-Close-Trip-180s-Close-Trip

     

    11

     

    Mechanical Life

    31.5kA

     

    Times

    30000

    40kA

    20000

    50KA

    10000

    12

    Rated Single Capacitor Group Breaking Current

    A

    630

    13

    Rated Back-to-Back Capacitor Group Breaking Current

    A

    400

    14

    Operating Mechanism Rated Closing/Tripping Voltage (DC)

    V

    100/200

    15

    Three-Phase Trip/Close Asynchronism

    ms

    ≤2

    16

    Contact Closing Bounce Time

    ms

    ≤2

    17

    Average Tripping Speed

    m/s

    0.91.2

    18

    Average Closing Speed

    m/s

    0.40.8